engineering innovation
engineering innovation
ISSI
Innovative Scientific Solutions Inc 2766 Indian Ripple Road Dayton, OH 45440-3638 937-429-4980


Low-Speed Measurements
The most challenging field of application for PSP is low-speed measurements. Standard PSP formulations have a pressure sensitivity of 600-1200Pa per 1% of intensity variation and a temperature sensitivity of about 600-1000Pa per degree Centigrade.
The pressure variation on the object moving with a velocity of 10m/s is only about 50..150Pa which implies severe requirements on the accuracy of intensity measurements, the uncertainty in the temperature field on the surface under study, and the stability of the image detector and excitation light sources. An additional problem is possible model deformation and displacement relative to the light source.
A possible practical solution is the use of Bi-Luminophore PSP with low temperature sensitivity.
More about Bi-Luminophore PSP

Pressure field on the side window of a real car (above). Ambient flow velocity of 100, 160 and 200 km/h; Uni-FIB PSP with TSP markers used for temperature-field estimation, with subsequent temperature compensation of pressure field.
Pressure distribution on the wheel (below).
Flow velocity is ~36m/s; wheel rotation velocity is ~72 RPS.